Updated Infinitude Compatibility Matrix (markdown)
Add Infinitude Compatibility Matrix Known-working thermostat/firmware combinations with Infinitude. Starts with SYSTXCCITC01 and SYSTXCCITC01-B at CESR131493-14.02. Includes equipment bus devices observed during development. Warns about firmware > 4.05 incompatibility.
Update a couple SAM-isms omitted from the last edit
Filled in some details about use of some of the SAM registers, esp 3B02 and 3B03; more to come later
Add System Setup Discovery Protocol page
Update framing protocol, RPi install, and Home Assistant pages - Framing Protocol: add exception code 0x04 detail, SAM bus master behavior, exception correlation data from overnight capture - RPi Install: add Docker as recommended method, update raspi-config instructions, add systemd service template, note firmware compatibility - Home Assistant: reference Infinitude Beyond HACS integration, add docker-compose for multi-thermostat, modernize config flow instructions
Add SAM ASCII Protocol page and update register map / known devices - New page: SAM ASCII Protocol (full command reference + observed bus behavior) - Updated: Register Map with SAM register space, device addresses, table definitions, polling frequencies, and 061F float decode analysis - Updated: Known Devices with new model confirmations and bus topology notes - Updated: Home page with link to new SAM ASCII Protocol page No serial numbers or personal information included.
Updated Infinity known devices (markdown)
Updated Installing Infinitude on Raspberry PI (Raspbian) (markdown)
Destroyed Installing Infinitude on Rasbian Troubleshooting ‐ DRAFT (markdown)
Created Installing Infinitude on Rasbian Troubleshooting - DRAFT (markdown)
Fix formatting on temp values.
Update outdoor unit temperatures as observed on Carrier 24VNA9.
Update 0306 for IndoorUnit representing indoor_airflow_cfm, appears to be updated faster than 0316.
Update 0604 table, first 2 bytes appear to be the "target" RPM while the 2nd set represents the actual value.
Add line voltage for Outdoor Unit
Updated Infinity Protocol Hardware (markdown)
Updated Infinity Framing Protocol (markdown)
Added static_pressure
Add 189BNV compressor RPM message
Move 0604 register to correct order
Remove invalid gas_valve_onoff variable, update explanation of gas_valve_percent variable, add explanation of 0316 'state' variable
gas_valve_onoff is inaccurate/incorrect on some 987M systems
Add 186CNV compressor RPM location correctly this time
Revert 946e1971af1d163d8ccd05e29f2a371bee6cbf19...d3fc6a602061e5b334d4f7d3bfb9303a5f04fd63 on Infinity interpreting data
Revert d3fc6a602061e5b334d4f7d3bfb9303a5f04fd63...a271c4989d599093acc6eb237027fcc29ad39f61 on Infinity interpreting data
Fix previous edit adding 186CNV compressor RPM value
Add 186CNV compressor RPM location