gomc-rest
gomc-rest is a small REST API server and HTTP gateway for Mitsubishi Electric PLCs using MC protocol 3E or 4E frames. It sits between HTTP clients and a PLC, brokering reads and writes for device strings such as D100.0, W100, and M0 while returning JSON values with automatic conversion: word devices become integers and bit devices become booleans.
The PLC transport is provided by gomcprotocol. The server uses only the Go standard library for HTTP handling.
A Python client library with no extra dependencies is also available: gomc-rest-client on PyPI
A lightweight debugging GUI is also available: gomc-rest-gui — a standalone HTTP client (Wails + React) for exercising gomc-rest's endpoints from a simple screen instead of curl.
Features
- Read word and bit devices through a simple
/readendpoint. - Write integer arrays or boolean arrays through
/write. - Run, stop, pause, latch-clear, and reset the PLC remotely.
- Configure by command-line flags, with environment variables as defaults.
- Start in read-only mode to block write and remote-control endpoints.
- Serialize PLC communication through a single in-process worker queue.
- Keep a simple health endpoint that reports the current connection state.
- Retry the PLC connection on demand when startup connection fails or a previous connection was cleared.
Network Scope
⚠️ Caution: Do not expose this server to the Internet, an office LAN, or any untrusted network.
This server is intended only for FA local networks, such as an isolated factory LAN, a trusted machine network, or localhost access from an operator PC. The API can read, write, run, stop, pause, latch-clear, and reset a PLC, and it does not provide authentication, authorization, TLS, or access control.
Recommended deployment:
- Run it inside an isolated FA network or on
localhostonly. - Restrict access with network segmentation, firewall rules, or host-level controls.
- Use
-listen 127.0.0.1:8080when only local access is required. - Do not place it behind a public reverse proxy or expose it through port forwarding.
Download
Download the latest gomc-rest.exe from the Releases page.
Published releases provide the Windows binary as gomc-rest.exe. Source builds use the output name from the build command below.
Quick Start (Windows)
1. Create a batch file
Create start-gomc-rest.bat in the same folder as gomc-rest.exe and edit the values at the top to match your environment:
@echo off
REM ============================================================
REM Edit these values to match your environment
REM ============================================================
set PLC_HOST=192.168.0.1
set PLC_PORT=5007
set LISTEN_PORT=8080
REM ============================================================
gomc-rest.exe -host %PLC_HOST% -port %PLC_PORT% -listen %LISTEN_PORT%
pause
Double-click the batch file to start the server. To stop it, press Ctrl+C or close the window. The pause line keeps the window open after the server exits so you can read any error messages.
2. Verify the server is running
Open a browser and go to:
http://localhost:8080/health
You should see:
{"plc_status":"ok","connected":true}
If the PLC is not reachable yet, connected will be false. The server still starts and will retry the connection on the first PLC operation (/read, /write, or /remote/*).
Read-only mode
To block all write and remote-control operations (for monitoring only):
@echo off
set PLC_HOST=192.168.0.1
set PLC_PORT=5007
set LISTEN_PORT=8080
gomc-rest.exe -host %PLC_HOST% -port %PLC_PORT% -listen %LISTEN_PORT% -readonly
pause
Save logs to a file
@echo off
set PLC_HOST=192.168.0.1
set PLC_PORT=5007
set LISTEN_PORT=8080
set LOG_FILE=C:\gomc-rest.log
gomc-rest.exe -host %PLC_HOST% -port %PLC_PORT% -listen %LISTEN_PORT% -log-file %LOG_FILE%
pause
Logs are written to both the console and the file. The directory must already exist; the server does not create missing parent directories.
Enable remote control
Remote-control endpoints (/remote/run, /remote/stop, etc.) are disabled by default. Add -enable-remote to turn them on:
gomc-rest.exe -host %PLC_HOST% -port %PLC_PORT% -listen %LISTEN_PORT% -enable-remote
Troubleshooting
| Symptom | Likely cause | Fix |
|---|---|---|
{"connected":false} on /health |
PLC is off or IP/port is wrong | Check PLC_HOST and PLC_PORT in the batch file |
403 forbidden on /write |
Server started with -readonly |
Remove -readonly from the batch file |
403 forbidden on /remote/* |
-enable-remote is not set |
Add -enable-remote to the batch file |
503 busy |
Too many simultaneous requests | Increase -queue-size (default: 32) |
| Port already in use | Another process is using the port | Change LISTEN_PORT to a free port |
| Window closes immediately | Startup error | Run from Command Prompt to see the error message |
Run
For the Windows release binary:
.\gomc-rest.exe -host 192.168.0.1 -port 5007 -mode binary -listen :8080
For source builds or non-Windows environments:
./gomc-rest -host 192.168.0.1 -port 5007 -frame 3e -transport tcp -mode binary -queue-size 32 -timeout 5s -listen :8080
For read-only operation, add -readonly. In read-only mode, /health and /read remain available, while POST operations on /write and /remote/* return 403 forbidden.
.\gomc-rest.exe -host 192.168.0.1 -port 5007 -mode binary -listen 127.0.0.1:8080 -readonly
On startup, the server attempts to connect to the PLC. If the PLC is not reachable, startup continues and the server retries on the first PLC request.
Build from source
git clone https://github.com/moge800/gomc-rest
cd gomc-rest
go build -o gomc-rest .
Configuration
Flags take priority. Environment variables provide the default values for those flags.
| Flag | Environment variable | Default | Notes |
|---|---|---|---|
-host |
GOMCR_HOST |
192.168.0.1 |
PLC host or IP address |
-port |
GOMCR_PORT |
5007 |
PLC port, 1 to 65535 |
-frame |
GOMCR_FRAME |
3e |
MC protocol frame, 3e or 4e |
-transport |
GOMCR_TRANSPORT |
tcp |
tcp or udp; 4e supports tcp only |
-mode |
GOMCR_MODE |
binary |
binary or ascii |
-queue-size |
GOMCR_QUEUE_SIZE |
32 |
Number of PLC requests that can wait while one request is active |
-timeout |
GOMCR_TIMEOUT |
5s |
PLC connect and I/O timeout |
-listen |
GOMCR_LISTEN |
:8080 |
HTTP listen address |
-readonly |
GOMCR_READONLY |
false |
Set to true to reject POST operations on /write and /remote/* |
-enable-remote |
GOMCR_ENABLE_REMOTE |
false |
Set to true to enable remote-control endpoints (/remote/*) |
-log-file |
GOMCR_LOG_FILE |
(none) | Path to log file; if set, logs are written to both the file and stderr |
-log-level |
GOMCR_LOG_LEVEL |
info |
Terminal log level: debug, info, warn, or error |
-log-file-level |
GOMCR_LOG_FILE_LEVEL |
warn |
File log level: debug, info, warn, or error; only used with -log-file |
API Reference
All successful write and remote-control operations return:
{"ok":true}
| Method | Path | Parameters / body | Response |
|---|---|---|---|
GET |
/openapi.yaml |
none | OpenAPI 3.1 specification (YAML) |
GET |
/version |
none | {"version":"v0.9.0"} or {"version":"dev"} for local builds |
GET |
/info |
none | {"version":"v0.9.0","gomcprotocol_version":"v0.3.0","host":"192.168.0.1","port":5007,"frame":"3e","transport":"tcp","mode":"binary","listen_addrs":["192.168.1.10:8080"],"readonly":false,"enable_remote":false} |
GET |
/metrics |
none | {"client_request_count":0,"busy_count":0,"client_avg_latency_ms":0,"client_recent_avg_latency_ms":0,"queue_length":0,"request_count":0,"reconnect_count":0,"timeout_count":0,"plc_error_count":0,"avg_latency_ms":0,"recent_avg_latency_ms":0} |
GET |
/health |
none | {"plc_status":"ok","connected":true} or {"plc_status":"disconnected","connected":false} |
GET |
/read |
query: addr required, count optional and defaults to 1, dword optional and defaults to false, sint optional and defaults to false |
{"values":[100,200]} or {"values":[true,false]} |
POST |
/write |
query: addr required, dword optional and defaults to false, sint optional and defaults to false; body: {"values":[1,2,3]} or {"values":[true,false]} |
{"ok":true} |
POST |
/random-read |
body: {"words":["D100","D200"],"dwords":["D300"]} |
{"words":[100,200],"dwords":[300]} |
POST |
/random-write |
body: {"words":[{"addr":"D100","value":1}],"dwords":[{"addr":"D300","value":65536}],"bits":[{"addr":"M0","value":true}]} |
{"ok":true} |
POST |
/remote/run |
requires -enable-remote; query: clear=0/1/2 optional, force=true/false optional |
{"ok":true} |
POST |
/remote/stop |
requires -enable-remote; none |
{"ok":true} |
POST |
/remote/pause |
requires -enable-remote; query: force=true/false optional |
{"ok":true} |
POST |
/remote/latch-clear |
requires -enable-remote; none |
{"ok":true} |
POST |
/remote/reset |
requires -enable-remote; none |
{"ok":true} |
Notes:
countmust be between1and1024.valuesmust be present and contain between1and1024items.- The
/writerequest body must be 1 MiB or smaller. - Word devices require integer values in the range
0..65535. Bit devices require boolean values. - When
dword=true, each value is an unsigned 32-bit integer in the range0..4294967295. The low 16 bits are stored in the register ataddrand the high 16 bits in the next register (addr+1). Only word devices supportdword=true. Withdword=true,countmust be512or less andvaluesmust contain512items or less (so that the actual word count sent to the PLC does not exceed1024). - When
sint=true, values are interpreted as signed integers. For word devices the range is-32768..32767; fordword=truethe range is-2147483648..2147483647. Only word devices supportsint=true. The PLC register bits are unchanged —sintonly affects how values are converted between JSON and the 16-bit register representation. /random-readacceptswordsanddwordsarrays of device address strings. Both default to empty; at least one must be non-empty. Only word devices (D,W,R, etc.) are allowed. Returns{"words":[...],"dwords":[...]}where word values are integers (0..65535) and dword values are unsigned 32-bit integers (0..4294967295)./random-writeacceptswords,dwords, andbitsarrays. Each entry is{"addr":"...","value":...}.wordsanddwordsrequire word devices;bitsrequires bit devices. Internally callsRandomWritefor words/dwords andRandomWriteBitsfor bits within one serialized job. Maximum 255 entries per array./remote/*endpoints are disabled by default and return403 forbiddenunless the server is started with-enable-remote. This is separate from read-only mode.- When read-only mode is enabled, POST operations on
/writeand/remote/*return403 forbidden. Read-only mode is a safety aid, not a replacement for network isolation, authentication, authorization, firewall rules, or PLC-side protection. - Boolean query flags (
dword,sint,force) accepttrueorfalse(case-insensitive, exactly once). Any other value (including empty or duplicated) returns400 bad_request. All endpoints reject unknown query parameters with400 bad_request(when the request passes earlier checks such as method, read-only, and remote-enabled validation). GET /healthalways returns HTTP200, even when the PLC is disconnected./remote/resetclears the TCP connection because the PLC closes it after reset./metricsPLC fields (request_count,avg_latency_ms,recent_avg_latency_ms) measure only the PLC wire time. Client fields (client_request_count,client_avg_latency_ms,client_recent_avg_latency_ms) measure the full round-trip including queue wait time.busy_countcounts requests rejected because the queue was full; these are excluded from the client latency averages.timeout_countcounts requests that returnedcontext.DeadlineExceeded(timed out before, during, or after queuing).
Device Addressing
Device addresses are case-insensitive and may include surrounding whitespace. The device prefix determines whether the API reads or writes words or bits.
| Type | Devices | JSON value type | Examples |
|---|---|---|---|
| Word | D, W, R, ZR, TN, STN, CN, Z, SW, SD |
integer | D100, ZR512, TN10, CN5 |
| Bit | X, Y, M, L, B, F, V, SB, SM, S, DX, DY, TC, TS, STC, STS, CC, CS |
boolean | M0, TC10, CC5, STC3 |
Timer and counter contacts and coils use two-letter prefixes: TC (timer contact), TS (timer coil), CC (counter contact), CS (counter coil). The single-letter forms T and C are not valid device names and return 400 bad_request.
The numeric address must be a non-negative integer. Unknown devices, missing numbers, non-numeric numbers, and negative numbers return 400 bad_request. The devices X, Y, B, SB, W, SW, ZR, DX, and DY use hexadecimal address numbers (e.g. X4F, Y12D2, W1D).
Word Device Bit Access
Append .N (single hex digit, 0–F) to a word device address to read or write a single bit within the 16-bit register.
D3500.0 ← bit 0 (LSB) of D3500
D3500.F ← bit 15 (MSB) of D3500
W1D.7 ← bit 7 of W1D (hex address 0x1D)
- Read returns
{"values": [true]}or{"values": [false]}. - Write body must be
{"values": [true]}or{"values": [false]}(exactly one element). The server performs a read-modify-write internally. dword=trueorsint=truecombined with bit access returns400 bad_request.countmust be 1;count=2or higher returns400 bad_request.- Appending
.Nto a bit device (e.g.M0.0) returns400 bad_request.
Error Responses
Errors are returned as JSON. Every error response includes both the HTTP status code and a machine-readable code in the body.
| Scenario | HTTP | code |
Example |
|---|---|---|---|
| Invalid parameter, body, address, count, or method | 400 or 405 |
bad_request |
{"status":400,"error":"addr is required","code":"bad_request"} |
/remote/* endpoint called without -enable-remote |
403 |
forbidden |
{"status":403,"error":"remote-control operations are disabled (use -enable-remote to enable)","code":"forbidden"} |
| Operation rejected by read-only mode | 403 |
forbidden |
{"status":403,"error":"operation not allowed in read-only mode","code":"forbidden"} |
/write body is too large |
413 |
bad_request |
{"status":413,"error":"body must not be larger than 1048576 bytes","code":"bad_request"} |
| PLC MC protocol error with an end code | 502 |
plc_error |
{"status":502,"error":"MC error 0x4000","code":"plc_error","end_code":"0x4000"} |
| PLC connection error | 503 |
connection_error |
{"status":503,"error":"connect: refused","code":"connection_error"} |
| PLC communication queue is full | 503 |
busy |
{"status":503,"error":"PLC communication queue is full","code":"busy"} |
| PLC communication queue is closed during shutdown | 503 |
queue_closed |
{"status":503,"error":"PLC communication queue is closed","code":"queue_closed"} |
| HTTP request context was canceled before completion | 499 |
request_canceled |
{"status":499,"error":"request canceled","code":"request_canceled"} |
| HTTP request context deadline expired | 504 |
request_timeout |
{"status":504,"error":"request timed out","code":"request_timeout"} |
Connection Behavior
- PLC requests are serialized through one shared in-process worker queue and one client connection.
- The worker executes one PLC request at a time. HTTP handlers do not call the PLC client directly.
-queue-sizecontrols how many PLC requests can wait while one request is active. When the queue is full, the server immediately returns503 busywithRetry-After: 1.-timeoutcontrols the PLC connect and I/O deadline. It does not cancel HTTP request contexts that are already disconnected; queued requests are skipped before execution if their request context is canceled.- If initial connection fails, the HTTP server still starts.
- If there is no active connection, the next PLC request attempts to reconnect.
- Connection-level MC protocol errors clear the connection so a later request can reconnect.
Examples
The /health endpoint can be used without a PLC. The other examples require a reachable PLC.
curl http://localhost:8080/health
curl "http://localhost:8080/read?addr=D100&count=3"
curl "http://localhost:8080/read?addr=M0&count=4"
curl "http://localhost:8080/read?addr=D100&count=2&dword=true"
curl "http://localhost:8080/read?addr=D100&count=3&sint=true"
curl -X POST "http://localhost:8080/write?addr=D100" \
-H "Content-Type: application/json" \
-d '{"values":[10,20,30]}'
curl -X POST "http://localhost:8080/write?addr=D100&dword=true" \
-H "Content-Type: application/json" \
-d '{"values":[100000,200000]}'
curl -X POST "http://localhost:8080/write?addr=D100&sint=true" \
-H "Content-Type: application/json" \
-d '{"values":[-1,-32768,32767]}'
curl -X POST "http://localhost:8080/write?addr=M0" \
-H "Content-Type: application/json" \
-d '{"values":[true,false]}'
# Random read/write — multiple non-contiguous addresses in one request
curl -X POST "http://localhost:8080/random-read" \
-H "Content-Type: application/json" \
-d '{"words":["D100","D200"],"dwords":["D300"]}'
curl -X POST "http://localhost:8080/random-write" \
-H "Content-Type: application/json" \
-d '{"words":[{"addr":"D100","value":10},{"addr":"D200","value":20}],"bits":[{"addr":"M0","value":true}]}'
# Remote-control endpoints require -enable-remote at startup
curl -X POST "http://localhost:8080/remote/run?clear=0&force=false"
curl -X POST "http://localhost:8080/remote/stop"
curl -X POST "http://localhost:8080/remote/pause?force=false"
curl -X POST "http://localhost:8080/remote/latch-clear"
curl -X POST "http://localhost:8080/remote/reset"
Documentation
¶