mk3

command module
v0.0.0-...-cd1cbc0 Latest Latest
Warning

This package is not in the latest version of its module.

Go to latest
Published: Jun 10, 2019 License: MIT Imports: 12 Imported by: 0

README

mk3

Build Status Build status Coverage Status

Command line interface for the Manzanita Micro USB Dongle Terminator. This is an alternative to the MK3 Digital Perl Scanner Software provided by Manzanita Micro.

Usage

Download the executable for your chosen platform from the releases page. Feel free to rename the executable to mk3 or mk3.exe depending on your chosen platform.

You will need to know the location of the USB serial port which the dongle is plugged into. The MK3 Digital Perl Scanner Software documentation describes how to find this for Windows as a COM port number. For Unix based systems you can use dmesg | grep tty as described in the link.

Examples
mk3 -dongle /dev/tty.usbserial-A904RBQ7 -realtime

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -cmd ./samples/get_settings.yaml

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -cmd ./samples/get_settings.yaml -addr 4

Options

Dongle Location (required)

The path to the USB port where the dongle is connected.

mk3 -dongle /dev/tty.usbserial-A904RBQ7
Path to Commands File

The path to the file containing the commands to execute against the bus. Available commands are listed in the all_commands.yaml file.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -cmd ./samples/get_settings.yaml
Change a Cards Bus Address

Changes the address of the first card found to the one given. This should be used when only one card is attached to the dongle. If more than one card is connect the first card found will be given the new address.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -new-addr=5
Bus Address to Execute Commands

A single bus address to target sending the command file to.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -cmd ./fixtures/trigger_lights.yaml -addr 1
Send Raw Command

Send a command as detailed in the MK3 Digital Perl User Manual Command List.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -raw "XXX"
Maximum Cell Address

Option to limit the number of cells that will be addressed on the bus. This is useful to stop the program early when you know the maximum number of cells.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -cmd ./fixtures/get_commands.yaml -max-addr=68 
Scan Bus for Cards

Scans the bus for all cards connected.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -scan-cards
mk3 -dongle /dev/tty.usbserial-A904RBQ7 -scan-cells -max-addr=68 
Scan Bus for Cells

Scans the bus for all cells on connected cards.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -scan-cells
mk3 -dongle /dev/tty.usbserial-A904RBQ7 -scan-cells -max-addr=68 
Realtime

This command loops once it reaches the last cell and is useful for monitoring when setting up a pack or as a log output.

mk3 -dongle /dev/tty.usbserial-A904RBQ7 -realtime
mk3 -dongle /dev/tty.usbserial-A904RBQ7 -realtime -max-addr=68

Outputs YAML to stdout with the following structure;

Timestamp int64
Address   int
SerialNum int
CellCount int
Volts     float32
MaxVolts  float32
MinVolts  float32
Temp      int

Setup Development Environment

Requires a Go environment.

git clone git@github.com:ricallinson/mk3.git $GOPATH/src/git@github.com/ricallinson/mk3
cd $GOPATH/src/git@github.com/ricallinson/mk3
go get ./...
go install

Testing

cd $GOPATH/src/git@github.com/ricallinson/mmz
go test

Coverage

cd $GOPATH/src/git@github.com/ricallinson/mmz
go test -covermode=count -coverprofile=count.out; go tool cover -html=count.out

Documentation

The Go Gopher

There is no documentation for this package.